Product Details:
Place of Origin: France
Brand Name: Maneurop reciprocating
Certification: CE
Model Number: MGZ125 HGZ125
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: negotiate
Packaging Details: wooden case
Delivery Time: 4-6 weeks
Payment Terms: T/T
Supply Ability: 500 sets per month
Contact Now
Detailed Product Description
Compressor: France Maneorop Cooling Type: Air-cooled
Temperature: High And Medium Function: Refrigeration And Freezer
Power: 3Ph/50Hz/60Hz Condition: Brand New
Name: Maneurop Air-cooled Condensing Unit Refrigerant: R404a,R134a
High Light:

3Ph Air Cooled Refrigeration Unit

,

Reciprocating Air Cooled Refrigeration Unit

,

Air cooled R404a Condensing Unit

MGZ125 HGZ125 Maneurop Reciprocating MTZ MT Series Air Cooled Refrigeration Unit R404a Condensing Unit

 

We assemble these condensing units with original Danfoss Maneurop compressors, brand condenser, refrigeration line parts.  

 

Maneurop brand original high-configuration condensing units meet current and future requirements for performance, noise, compact manufacturing quality, and compliance with ecological standards.

 

Maneurop condensing unit is specially designed for a variety of purposes, with a wide range of operating conditions.

 

In order to ensure the long life of the Maneurop condensing unit, all the parts are of high quality and precision machining.

 

The unit consists of a compressor, a condenser, a liquid storage tank and a junction box. The unit consists of a single pressure switch, a double pressure switch, a filter, a liquid-viewing mirror and an electromagnetic valve.


Specifications:

 

R22 Model Horse Power Cooling capacity Connecting tube dimension(mm) installation size(mm)
HP w return gas(mm) outlet(mm) A B C a b
MT28/FH22H 2.5 4700 12 10 870 650 570 820 420
MT36/FH33H 3 6010 16 10 920 700 570 880 470
MT50/FH37.5H 4 7400 22 12 920 700 570 880 470
MT64/FH49H 5 9780 22 12 1020 700 670 980 460
MT80/FH70H 6.7 12380 28 16 1220 850 1080 1180 610
MT100/FH80H 8 14340 28 16 1220 850 1080 1180 610
MT125/FH100H 10 19190 28 16 1440 850 1280 1400 610
MT160/FH130H 13 24090 28 16 1220 850 1080 1180 610
MT28/FH18M 2.5 2730 12 10 640 545 520 590 315
MT36/FH22M 3 3560 16 10 870 650 570 820 420
MT50/FH33M 4 4280 22 12 920 700 570 880 470
MT64/FH42M 5 5690 22 12 1020 700 670 980 460
MT80/FH55M 6.7 7330 28 16 1220 850 770 1180 610
MT100/FH70M 8 8210 28 16 1220 850 1080 1180 610
MT125/FH80M 10 11450 28 16 1440 850 1280 1400 610
MT160/FH115M 13 14460 28 16 1440 850 1280 1400 680

 


 

Model/Code HP Cooling capacity Connecting tube cooling water consumption m3/h dimension(mm) installation size(mm)
HP w return gas(mm) outlet(mm) A B C a b
MT36/WN03M 3 4330 16 10 1.3 810 300 600 600 250
MT50/WN05M 4 5210 22 12 1.6 1010 350 720 780 300
MT64/WN05M 5 6740 22 12 2 1010 350 720 850 300
MT80/WN08M 6.7 8580 28 16 2.6 1080 350 720 890 300
MT100/WN10M 8 10210 28 16 3.2 1120 350 800 890 300
MT125/WN10M 10 13710 28 16 4 1120 350 800 990 300
MT160/WN15M 13 17300 28 16 5.2 1220 400 800 780 350
MT36/WN05H 3 6980 16 10 1.4 1010 350 720 780 300
MT40/WN05H 3.5 7570 22 12 1.6 1010 350 720 780 300
MT50/WN06H 4 8680 22 12 2 1010 350 720 850 300
MT64/WN08H 5 11320 22 12 2.6 1080 350 720 890 300
MT80/WN10H 6.7 14250 28 16 3 1120 350 800 890 300
MT100/WN10H 8 17120 28 16 3.2 1120 350 800 890 300
MT125/WN15H 10 22510 28 16 4.9 1220 400 800 990 350
MT160/WN15H 13 28250 28 16 5.2 1220 400 800 990 350

 

Features:

 

1. The special design of Maneurop condensing unit makes the motor in the compressor cooled 100% by suction.

 

2. Maneurop condensing unit adopts High Efficiency Ring Valve design and high torque motor for internal protection, which is safe and reliable.

 

3.Maneurop condensing units use specially designed Pistons, ultra-strong Coil Insulation, built-in silencers and low noise operation.

 

4. Maneurop condensing units adopts PTC crankcase heater to prevent refrigerant from dissolving into lubricating oil, ceramic head at the bottom of oil tank to prevent magnetic impurity from entering the motor and cylinder.

 

5. Maneurop condensing unit supports Spring to reduce vibration and stress, the Maneurop condensing unit is equipped with a negative pressure oil pump, which keeps continuous lubrication and prolongs the life of the compressor unit.

 

6. The unit is highly efficient in saving electricity and using no water, high efficiency and energy saving.

 

 
MGZ125 HGZ125 Maneurop Reciprocating Air Cooled Refrigeration Unit R404a Condensing Unit 0
 
 

 

Contact Details
Shenzhen Sino-Australia Refrigeration Equipment Co., Ltd.

Contact Person: Jason

Tel: 86-13480948557

Fax: 86-755-82209876

Send your inquiry directly to us (0 / 3000)

Other Products