Send Message
Home ProductsAir Cooled Refrigeration Unit

2900rpm 3HP Air Cooled Refrigeration Unit Copeland Hermetic ZB21KQE

2900rpm 3HP Air Cooled Refrigeration Unit Copeland Hermetic ZB21KQE

  • 2900rpm 3HP Air Cooled Refrigeration Unit Copeland Hermetic ZB21KQE
  • 2900rpm 3HP Air Cooled Refrigeration Unit Copeland Hermetic ZB21KQE
2900rpm 3HP Air Cooled Refrigeration Unit Copeland Hermetic ZB21KQE
Product Details:
Place of Origin: China
Brand Name: Copeland
Certification: CE / CCC
Model Number: 3HP
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: negotiate
Packaging Details: wooden case
Delivery Time: 4-6 weeks
Payment Terms: T/T
Supply Ability: 500 sets per month
Contact Now
Detailed Product Description
Compressor: Copeland Scroll ZB Cooling Type: Air-cooled
Temperature: Medium Temperature Function: Cooling
Power: 380V/3PH/50HZ Condition: Brand New
Name: Chiller Room Refrigeration Unit Refrigerant: R404a
High Light:

3HP Air Cooled Refrigeration Unit

,

2900rpm Air Cooled Refrigeration Unit

,

Hermetic Cold Room Condensing Unit

ZB21KQE 3HP Copeland Hermetic Scroll Refrigeration Unit Cold Room Condensing Unit

 

Compressor: Copeland scroll ZB series

 

Capacity:3HP

 

Refrigerant:R404a

 

Voltage:380V/3PH/50HZ

 

Low noise, Energy saving, Easy installation,Copeland scroll compressor

 

Description

 

The Copeland refrigeration scroll compressor represent the newest technology of the refrigeration compressor, that is with the small size, low noise, little weight, energy saving, reliable and low price. To a large extent, the scroll compressor will take the place of the traditional piston compressor.

If the three phase scroll condensing unit is with the phase order and phase missing protector, then that can effectively prevent the compressor from the damage by its reverse and power missing.

 

Features

 

1. Electric components :main control board, cold room temp control board and operation board.

2. With fan speed regulator, to adjust condensing fan according to condensing temp.

3. With operation data display function, to check operation current of compressor, discharge temp. and condensing temp.

4. With system alarm function. When fault effects, the system will make alarm beep sound to remind user.

5. The operation board can show temp. setting, defrosting control, operation system data checking and cold room temp. alarm functions. It can be installed apart from condensing units for remote control.

 

Specifications

 

Condensing unit Displacement Max.Oper. Current Fan Qty Air flow Overall Dimension Tube Connection Gross Weight
m3/h A No. m3/h L (mm) W (mm) H (mm) SL inc FL inc Kg
ZB15KQE 5.9 6.48 1 4235 700 675 505 3/4" 3/8" 65
ZB19KQE 6.8 6.58 1 5580 735 700 540 3/4" 3/8" 70
ZB21KQE 8.6 8358 1 5580 735 700 540 3/4" 3/8" 72
ZB26KQE 9.9 10.58 1 5580 735 700 540 3/4" 3/8" 76
ZB29KQE 11.4 11.85 1 7620 735 700 800 7/8" 3/8" 90
ZB38KQE 14.5 13.35 1 7620 735 700 800 7/8" 3/8" 98
ZB45KQE 17.2 16.95 1 7620 735 700 800 7/8" 1/2" 100
ZB48KQE 18.8 18.16 2 11160 1190 800 800 7/8" 1/2" 145
ZB58KQE 22.1 24.16 2 11160 1190 800 700 1 1/8" 5/8" 182
ZB66KQE 25.7 25.36 2 11160 1190 800 700 1 3/8" 5/8" 201
ZB76KQE 28.8 28.60 2 15240 1400 800 860 1 3/8" 5/8" 217
ZB95KQE 36.4 32.70 2 22320 1620 800 1250 1 3/8" 5/8" 237
ZB114KQE 43.4 40.32 2 22320 1190 800 1250 1 3/8" 5/8" 280
ZSI09KQE 8.04 2 1 3150 570 700 440 3/4" 3/8" 60
ZSI11KQE 9.95 3 1 5580 735 700 540 3/4" 3/8" 76
ZSI15KQE 14.37 3 1 5580 735 700 540 7/8" 3/8" 79
ZSI18KQE 17.06 6 1 5580 735 700 540 7/8" 1/2" 84
ZSI21KQE 20.9 14 2 11160 1190 800 650 1 1/8" 5/8" 176

 

The theoretical displacement when the compressor revolving speed is 2900rpm.

The maximum of the allowed lowest voltage (50Hz)

 

 

Contact Details
Shenzhen Sino-Australia Refrigeration Equipment Co., Ltd.

Contact Person: Jason

Tel: 86-13480948557

Fax: 86-755-82209876

Send your inquiry directly to us (0 / 3000)